conteHome > Smart Array > Hp Smart Array P420 Driver

Hp Smart Array P420 Driver

Contents

Enhancements  Increased performance of SATA drives by increasing command queue depth. Change product Choose from all HPE products Enter product serial number Please wait while we process your request. HP 6G SATA drives in HP D2000 Disk Enclosures were not detected after system was rebooted. After hot-plug replacement of a hard disk drive, incorrect hard disk drive firmware version and upgrade recommendation were displayed by HP Smart Storage Administrator. weblink

Configurations with SSD devices or a larger drive count (determined by the presence of a SAS expander in the topology) will continue to run at full memory speed. When an HP Smart Array P420 controller was attached to both an expander backplane and non-expander backplane, the controller would not properly control SmartCarrier LEDs. Uncorrectable ECC errors causing controller to hang (Lockup 0x13).  Smart Array memory will now run at a slower speed in configurations with a low hard drive count (generally 8 or less).  Configurations Added support for expander-based hard drive backplanes.

Smart Array P420i Latest Firmware

Uncorrectable ECC errors causing controller to hang (Lockup 0x13). Version:7.02 (1 Apr 2016) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. Reboot your system if you would like the update to take effect immediately. Sign-in Register Site help Skip to ContentSkip to FooterSolutionsHybrid IT with CloudMobile & IoTIT for Data & AnalyticsPublic SectorService ProvidersSmall & Midsize BusinessFinancial ServicesHealth & Life SciencesManufacturingTelecommunications All Solutions ServicesAdvisory and

Enhanced firmware to prevent the possibility of data loss due to a rare and intermittent failure when flashing firmware for the HP D2600 or D2700 SAS Disk Enclosures (refer to Customer By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomPublic PolicySitemapPartnersPartnersFind a Added support for attaching the HP MDS600 Disk Enclosure (SAS only) to HP Smart Array P721m controllers. Smart Array P420i Cache Module Warranty status only indicates current warranty state.

Firmware displayed the incorrect POST error message (1705 instead of 1800) in the event of a Smart Array flash back write cache charging failure. Smart Array P420i User Guide Disable Tech Support Mode on the ESXi host Reboot your system if you would like the update to take effect immediately. Drive temperatures for SATA drives might not be reported after hot-inserting the drive. http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=5295169 When drive write-cache is enabled, protocol errors are observed.

Link 2. Hp Smart Array P420 Controller Battery Replacement ORCA now correctly displays the type of attached drives after hot replacement of an SSD. When booting the server, the controller may intermittently fail to be discovered due to a problem initializing the controller. ORCA now correctly displays the type of attached drives after hot replacement of an SSD.

Smart Array P420i User Guide

End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMéxicoNederlandNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=5295170&swLangOid=2&swEnvOid=4139 Problems Fixed: The rare occurrence of 0x13 lockup is no longer observed in Linux while running I/O. Smart Array P420i Latest Firmware SATA SSD’s were incorrectly marked as worn out. P420i Controller Login as root. (You must be root in order to apply the ROM update.) Place the Smart Component in a temporary directory.

Chkdsk was running slowly. http://3podjobs.com/smart-array/hp-smart-array-p410i-drivers.php For example: ./CPXXXXXX.scexe Follow the directions given by the Smart Component. Version:3.54 (8 May 2013) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. In some cases, incorrect drive temperatures were reported in an HP D2220sb enclosure, resulting in a system shutdown. Dl380p Gen8 Firmware

Select a server or cluster in the inventory tree. Logical drive remained in ‘Ready for recovery’ state when the drive was re-enabled after failing during a transformation. This would cause the component installation to end with a return code 3 (already up to date) and a force install would be required to successfully update the FW. http://3podjobs.com/smart-array/hp-smart-array-drivers.php A controller lockup could occur if the controller was configured with a SmartCache smaller than 8GB.

VMware might hang when a VM with 2 or more RDMs used a Smart Array controller to access an HP P2000 G3 or HP MSA 2040 SAN storage device. Hp Smart Array P830i Controller Firmware In some cases, when the power was applied to the system, the Smart Array controller would report that the supercap was charging even though charging had completed. HP 6G SATA drives in HP D2000 Disk Enclosures were not detected after system was rebooted.

Volume was not failed when expansion was aborted due to multiple bad blocks.

Version:8.00 (24 Oct 2016) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. A controller lockup (0xAB) might occur with SATA drives. An intermittent aborted IO request with attached SATA drives resulted in a LUN (Logical Unit Number) reset. P420i Hba Mode Problems Fixed: Firmware version 3.22 has resolved the following problems: A temperature reporting issue caused the fans in a BladeSystem c-Class enclosure to ramp up and down when the blade servers

Problems Fixed in version 6.00: This firmware release resolved the following issues: When executing kdump on systems running in Zero Memory RAID (ZMR) mode, the controller might halt. Follow HP Smart Update Manager steps to complete firmware update. Volume was not failed when expansion was aborted due to multiple bad blocks. http://3podjobs.com/smart-array/hp-smart-array-p420i-drivers.php For additional information please refer to the customer advisory # c04602001 When a controller was set to RAID6 mode and a large number of recoverable errors were generated by hard disk

Problems Fixed: Firmware version 3.22 has resolved the following problems: A temperature reporting issue caused the fans in a BladeSystem c-Class enclosure to ramp up and down when the blade servers ORCA now correctly displays the type of attached drives after hot replacement of an SSD. Firmware displayed the incorrect POST error message (1705 instead of 1800) in the event of a Smart Array flash back write cache charging failure. Improved RAID 1 performance for small block random write workloads on SSD configurations.

The actual name of the 'hp-firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above The results of the firmware upgrade are saved to the Component.log Improved RAID 1 performance for small block random write workloads on SSD configurations. Version:7.5 (24 Oct 2016) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. Problem Fixed for Firmware Version 4.68(B): A decimal conversion was not being interpreted correctly when installing the component under certain regional settings in Windows.

VMware might hang when a VM with 2 or more RDMs used a Smart Array controller to access an HP P2000 G3 or HP MSA 2040 SAN storage device. Enhancements: Controller performance for small block sequential mixed read/write benchmark. A controller lock up (0xBC) might occur while reconfiguring a controller with a failed logical drive or a failed cache module. End User License Agreements:Hewlett-Packard End User License Agreement Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.

Problems Fixed: The rare occurrence of 0x13 lockup is no longer observed in Linux while running I/O. Problems Fixed: Firmware version 3.22 has resolved the following problems: A temperature reporting issue caused the fans in a BladeSystem c-Class enclosure to ramp up and down when the blade servers This issue is due to changes in the OS where the sg driver is no longer loaded during system boot.

nt