conteHome > Smart Array > Hp Smart Array P410i Controller Driver Linux

Hp Smart Array P410i Controller Driver Linux

Contents

Added a new POST message 1813 to indicate bad or failed battery charge circuit. Controllers configured with one or more SATA spare drives and firmware version 6.40 (or earlier) may halt with "Lockup Code = 0xAB" after 64, 128, or 256 days. Controllers configured with one or more SATA spare drives and firmware version 6.40 (or earlier) may halt with "Lockup Code = 0xAB" after 64, 128, or 256 days. Fixed an issue where a controller configured for 100% read cache could cause a false "A cache error was detected. weblink

the drive, the controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. If you're already running cciss on these devices, and upgrade to a kernel containing the hpsa driver, you shouldn't have to do anything, as cciss will continue to claim these devices. Reference Customer Advisory c03011608. the drive, the controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=3902577

Smart Array P410i Firmware

The actual name of the 'hp-firmware-smartarray-14ef73e580-*' folder is based on the version of the rpm installed in the first step above To install firmware, you can execute ONE of the following commands:      Enhancements/New Features for 6.60 (B): Added support for SUSE Linux Enterprise Server 12 Version:6.60 (9 Sep 2014) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. Fixed a panic that could arise during an insmod and rmmod of the cciss driver.

From kernels 2.6.11 to 2.6.15 is kind of a gray area during which some kernel interfaces the driver relies upon were in flux. Fixed an issue where the hot-add of a 3TB drive to HP DL180G6 12 drive backplane could cause the controller to lock up (code 0x15). Version:6.6 (9 Sep 2014) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. Hp Smart Array P410i Setup Problems Fixed in version 6.60: This firmware release resolved the following issues: After a mode toggle at EFI ORCA was performed, the controller name would not be displayed when running the

Customers who already installed firmware version 6.40 do not need to update to 6.40 (B). Hp Smart Array Software Problems Fixed: Fixed an issue where Bios on HP ProLiant 100 series servers could not designate a boot controller when more than 1 HP Smart Array P212, P411, or P410 controller For additional information, reference the Customer Advisory available at the following URL: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02437391      To support Dual Domain on HP StorageWorks D2000 enclosures, the D2000 must be at a minimum firmware http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=3902575&swLangOid=8&swEnvOid=4064 SAS hard drives are not affected by this issue.

Reference CA c03127437. Hp Smart Array P410/512 Firmware The Open Connection timeout was reduced to 900 microseconds so that SAS connections terminate gracefully and data transfer stalls are prevented. Looking for printers, tablets, and desktops? Warranty status: Unspecified Check warranty status Drivers & software Help Knowledge base options Search HPE Support Center - HPE Most viewed solutions Advisories, bulletins & notices Manuals Troubleshoot a problem Setup &

Hp Smart Array Software

An issue that resulted in never completing an IO request after outstanding read and write requests overlapped the same block range. http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5fd5115aa67541039563575a0f Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Smart Array P410i Firmware After the Smart Array device driver 'hpsa' was upgraded to version 3.4.6-165 on Red Hat Enterprise Linux 6 Update 4 or Update 5 on a server configured with logical volumes on Hp Smart Array P410i Manual This issue can potentially cause controller hang with no lockup code as a result.

HP does supply binary RPMs and driver diskettes (for loading drivers during OS installation) for supported Linux distributions on hp.com. http://3podjobs.com/smart-array/hp-smart-array-p410i-drivers.php RHEL 4.x and SLES 9.x are examples of systems based upon such kernels. Oct 4, 2007: Note: There has been a report that sometimes the OS supplied /sbin/mkinitrd script used by the RPM will get the wrong cciss.*.ko file out of /lib/modules/`uname -r`/kernel/drivers/block and Place the firmware to be updated in the directory, /compaq/swpackages on the USB key. Smart Array P410i Battery

It reports any status changes, like failing disks, to the syslog and optionally to a remote host using SNMP traps." This program works by monitoring events from Smartarray controllers, originally written If the MDS600 has version 2.60 firmware, then it can be connected to the HP Smart Array P812 controller. It neither modifies bootloader (grub or lilo.conf) configuration files, nor modify /etc/modules.conf, nor build initrd. check over here Reference Customer Advisory c03011608.

Download details not available at this site. Hpe Smart Array P410i Controller The POST was indicateding a bad Super-Cap, which in turn disabled write caching. Version:6.64 (15 Jun 2015) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.

Corrected thermal behavior with HDDs.

Only the HP Smart Array P711m and P712m controllers are supported by firmware version 4.02. The hpsa driver has the ability to claim unknown Smart Arrays, however this is turned off by default so that it does not try to claim older controllers meant to be The function prints a message then retries the command that returned with a unit attention. P410i Maximum Drive Size Warranty status only indicates current warranty state.

End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMéxicoNederlandNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth To build the source tarballs: Create a directory and unpack the tarball. [[email protected] somedir]$ mkdir cciss-3.6.14 [[email protected] somedir]$ cd cciss-3.6.14 [[email protected] cciss-3.6.14]$ tar xzvf ../cciss-3.6.14.tar.gz configure Documentation/ Documentation/mkdev.cciss Documentation/cciss.txt Documentation/rmdev_dyn.cciss Documentation/mkdev_dyn.cciss Wehn reboot occurred, a reboot 1719 POST error message with lockup 0x15 displayed. this content On an HP P812 controller, executing several sequential Write operations to more than 75 hard drives would result in a controller lockup.

Fixed a panic that could arise during an insmod and rmmod of the cciss driver. Version:6.60 (B) (30 Mar 2015) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. In these instances you may wish to try the source RPMs or tarballs provided here. CCISS 2.4 source RPMs CCISS_2.4 source tarballs Use these for 2.4 based kernels, such as RHEL 3.x, SLES 8 or (SuSE) United Linux 1.0.

Added dynamic outstanding command turning on a per controller basis. If necessary, deb package will compile kernel as well. Should work on most any linux and FreeBSD (no MSA1000 support for FreeBSD though. Problems Fixed: On systems configured with HP Smart Array P711m controllers connected to logical volumes on HP P2000 G3 SAS storage arrays, the Smart Array device driver ‘hpsa’ would cease to

Was the information on this page helpful?

nt