Protection has been added to prevent potential Smart Array controller hangs under rare conditions when hot-adding hard drives. Problems Fixed: On systems configured with HP Smart Array P711m controllers connected to logical volumes on HP P2000 G3 SAS storage arrays, the Smart Array device driver ‘hpsa’ would cease to Fixed an issue where the controller would lock up (code 0xBC) due to incorrectly placing host data into a write-cache line that had a memory error. Fixed an issue where disk location information was reported incorrectly in the HP DL580 G5 with the HP SAS Expander card Fixed an issue where a RAID 6 volume could have weblink

I have brought your issue to the appropriate team within HP. Run a diagnostic report for more information" error to be displayed in the 'Cache Status Details' column in ACU. Was the information on this page helpful? Key features Seamless upgrades from past generations and upgrades to next generation HP high performance and high capacity Serial Attached SCSI Smart Array controllers.

Hp P212 Quickspecs

Problems Fixed:   Resolved the following issues: An issue resulting in a server hang during the boot process when a Smart Array controller is configured without a cache module. Controller displayed a POST error message 1805 “Cache Module Super–Cap is not installed” when the controller was configured to work without super-capacitors. Fixed an issue in which 3TB drives were not managed as spares. Fixed an issue that caused a lockup (code 0x13) with a SSD RAID 10 array under heavy I/O load.

the drive, the controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. For additional information, reference Customer Advisory c03011608 at the following URL: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03011608 Version:5.08 (16 Aug 2011) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.Firmware Version Customers could not invoke ORCA via command line interface, by pressing the escape key-strokes “Esc+6” or "F6" or “Esc+8” or "F8" via the BIOS Serial Console. 462834-b21 After a system with (2) or more empty SAS storage boxes, Box 1, 2, 3 …, attached to an HP SAS Expander card is powered up and then a drive is

On rare occasions the controller would become unresponsive during POST. Hp Smart Array P212 Controller Manual Flash-based cache modules caused a controller failure at POST, displaying one of the following error messages: ·          1783-Slot # Drive Array Controller Failure ·          1719-Slot [x] Drive Array - Note:  Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Running SMARTCTL (smartmontools) on HP Proliant G6/G7 (Px1x) Smart Array controllers that have firmware version 5.70 to 6.62 installed with SATA drives attached may result in system not responding or reboot.

To use HP Smart Update Manager from the HP Service Pack for ProLiant: Offline: Place the HP Service Pack for ProLiant on a USB key using the HP USB Key Creator Hp Smart Array P212/zm Added a new POST message 1813 to indicate bad or failed battery charge circuit. Fixed an issue where SATA disks could occasionally be marked as failed or missing during boot when no cache module is installed on the controller. Enhancements/New Features for 6.60 (B): Added support for SUSE Linux Enterprise Server 12 Version:6.60 (9 Sep 2014) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.

Hp Smart Array P212 Controller Manual

Notes: Deliverable Name:    Online ROM Flash Component for Windows - Smart Array P212, P410, P410i, P411, and P812  Release Version and/or Date:      5.12 Last Recommended or Critical Version:      5.12 Previous Version http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=3890398&swLangOid=2&swEnvOid=4168 Corrected thermal behavior with HDDs. Hp P212 Quickspecs Fixed an issue where the controller would lock up (code 0xBC) due to incorrectly placing host data into a write-cache line that had a memory error. P212 Firmware Android Version:6.40(B) (18 Oct 2013) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.

Select driver language and OS Driver language Chinese (Simplified) Chinese (Traditional) English French German Italian Japanese Korean Spanish Operating systems in English Select your product's operating system Microsoft Windows Server 2003 http://3podjobs.com/smart-array/hp-smart-array-p212-linux-driver.php These products are now supported by Hewlett Packard Enterprise. End User License Agreements:Hewlett-Packard End User License Agreement Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.Firmware Version 5.12 only applies to HP Smart Array P212, Fixed an issue where after hot-adding a SATA disk to an MSA-60, MSA-70, or HP DL180-G6 12-drive backplane, the storage controller could become unresponsive. Hp Smart Array P410i Controller Firmware

Reference CA C03161926. Version:6.62 (6 Apr 2015) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience. Enhancements Enhancements/New Features:  Enhanced the controller SAS discovery logic to tolerate devices that may be resetting. http://3podjobs.com/smart-array/hp-smart-array-p212-controller-driver-download.php Fixed an issue where removal of a HP P2000saG3 controller module could cause a controller lockup (code 0xAB).

End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMéxicoNederlandNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth Hp P212 Max Drive Size An apparent hot-swap of a disk drive is reported even though the drive was not physically hot-plugged. Fixed an issue where the controller could become unresponsive while handling a hot-removal event when experiencing heavy I/O.

top Provide feedback Please rate the information on this page to help us improve our content.

Customers who already installed firmware version 6.40 do not need to update to 6.40 (B). Corrected thermal behavior with HDDs. Before connecting the MDS600 to the HP Smart Array P812, you must first flash the HP Smart Array P812 to firmware version 3.50 or greater. Smart Array P212 Battery Fixed an issue where a controller running with no cache module, attached to SATA disks, could encounter a lockup (code 0x15) when running HP Insight Diagnostics software or offline HDD firmware

Type: Firmware - Storage Controller Version: 5.12(30 Sep 2011) Operating System(s): Microsoft Windows Server 2003 Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 W32 Microsoft Windows Server When running heavy I/O in RAID 5, while an HP P410 controller was connected to more than 17 SAS drives in an HP DL180 G6 server with a 25SFF backplane, a Corrected thermal behavior with HDDs. http://3podjobs.com/smart-array/hp-smart-array-p212-zero-memory-controller-driver.php Version:6.64 (15 Jun 2015) Fixes Upgrade Requirement:Recommended - HP recommends users update to this version at their earliest convenience.

Important Notes: Reference Customer Advisory c03793656 - Windows Server 2012 - HP ProLiant Server May Blue Screen if Configured With an HP Smart Array Controller and the Windows Server 2012 HPCISSS2.SYS These return codes indicate the completion status of the component installation. Customers with the HP DL165 G7 or DL170e G6 server should remain at HP Smart Array FW version 3.66. Enhancements/New Features for 6.60 (B): Added support for SUSE Linux Enterprise Server 12 Problems Fixed in version 6.60: This firmware release resolved the following issues: After a mode toggle at EFI

Reference Customer Advisory c03011608. Problems Fixed: There is a potential data transfer issue if the following Smart Array controllers P212, P410, P410i, P411, or P812 are attached to certain models of the SATA hard drives. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. Smart Array FW version 5.06 will not log HDD and Smart Array Controller POST error messages to the Integrated Management Log (IML).

Upon power up, a Post message will now be displayed to the user to indicate that a cache module is needed for the P711m controller. Fixed an issue where simultaneous handling of many Unrecoverable Read Errors on SATA disks supporting Native Command Queuing could result in a lockup (code 0x15). Problems Fixed in version 6.60: This firmware release resolved the following issues: After a mode toggle at EFI ORCA was performed, the controller name would not be displayed when running the