conteHome > Hp Smart > Hp Smart Array Controller 6400 Drivers

Hp Smart Array Controller 6400 Drivers

Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes. Fixed an issue where inquiries to the logical drive would succeed even after the drive is physically removed. To avoid notification during the POST routine, update any applicable hard disk drives before updating the Smart Array firmware. Environment Tracking for External Storage System monitors. weblink

Added an enhancement to allow an occasional SCSI command timeout without downshifting the SCSI bus to a lower speed.4. Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked RAID ADG provides fault protection greater than RAID 1 or RAID 5 and only consumes the capacity of 2 disk drives for distributed parity data. Your message has been reported and will be reviewed by our staff. http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=348785&swLangOid=8&swEnvOid=4068

For example: ./CPXXXXXX.scexe Follow the directions given by the Smart Component. Included additional changes in the SCSI ID detection algorithm for server configurations involving duplex backplanes. Enhancements 1. This component contains version 1.60 firmware.

Designed and tested with industry standard ProLiant Servers for greater reliability, this controller is ideal for workgroup and departmental servers. ECC-Protected Cache Memory: Removable, battery-backed cache memory protects data, up to four days (three days with 256-MB Module), in the event of power failure, server hardware failure or controller failure. Fixed an issue that would downshift the entire bus for a single parity error. Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked

Fixed spare drive handling when executing split mirror and mirror resynchronization commands.6. Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage systems. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. Place the firmware to be updated in the directory, /compaq/swpackages on the USB key.

HP Care Pack services are prepaid. Driver version 5.60.0.32 and newer added support for the HP Smart Array 6i controller. Fixed Array behavior to prevent unwanted device migrations by detecting conditions, where a SCSI disk drive unexpectedly changes its SCSI ID. 3. Close E-mail This Review E-mail this to: (Enter the e-mail address of the recipient) Add your own personal message:0 of 1,000 characters Submit cancel Thank You, !

Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator. Version:2.76 (A) (20 Mar 2007) Fixes Fixed an issue where the SA6404 would lock-up and cause Windows to blue-screen when installing or upgrading the Smart Array device driver in a server with Enhancements Updated recommended hard drive firmware list with models that have been experiencing excessive SCSI command timeouts.  When one of these drives is present, user will see a POST message recommending he Fixed an issue that can occur during configuration (with the ACU) of an MSA20 or MSA500.  In a Windows environment, the issue can result in a blue-screen condition.  2.

Driver version 5.48.0.32 and newer added support for the HP Smart Array 6404 controller. have a peek at these guys This reduces the risk of flashing firmware to the controller. Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked If you have previously upgraded to version 2.62 firmware another update is not needed.2.

Click here to obtain the list of affected disk drive models. To use HP Smart Update Manager on the Firmware Maintenance CD version 7.50 and later: Place the Firmware Maintenance CD on a USB key using the HP USB Key Creator Utility. Removed the F1 prompt from the POST routine when recommending disk drive firmware updates. check over here Version:2.80(B) (25 Sep 2007) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Select type of offense: Offensive: Sexually explicit or offensive language Spam: Advertisements or commercial links Disruptive posting: Flaming or offending other users Illegal activities: Promote cracked software, or other illegal content Enhancements Improved the flash update process.

Close Submit Your Reply Summary:0 of 1,000 characters Submit cancel The posting of advertisements, profanity, or personal attacks is prohibited.Click here to review our site terms of use.

Added POST message 1717 "Disk Drive(s) Reporting OVERHEATED Condition".7. Designed and tested with industry standard ProLiant Servers for greater reliability, this controller is ideal for workgroup, departmental, and enterprise servers. Enhancements Updated recommended hard drive firmware list with models that have been experiencing excessive SCSI command timeouts.  When one of these drives is present, user will see a POST message recommending he Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution.

Proof of purchase may be required. Click here to obtain the list of affected disk drive models. Installation Instructions Prerequisites: This Smart Array firmware will recommend updates for some SCSI disk drive models after the Smart Array firmware has been installed. this content Please note:The previous release of the Online ROM Flash Component for Windows, firmware version 2.26, required an updated Windows driver for operation.

This helps prevent overcharging the battery, which can contribute to premature battery failures. This helps to maintain the capacity of the battery in the event data was trapped in the cache over the specified backup duration.Updated the battery firmware to keep the charge capacity Version:1.92 (C) (8 Apr 2004) Fixes Modified the installer for remote installation support. Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked

To use HP Smart Update Manager on the Firmware Maintenance CD version 7.50 and later: Place the Firmware Maintenance CD on a USB key using the HP USB Key Creator Utility. Summary: (10 characters minimum)0 of 1000 characters Submit The posting of advertisements, profanity, or personal attacks is prohibited.Click here to review our site terms of use. You are logged in as . Added error handling in the controller firmware to fail a disk drive if an unwanted SCSI ID change occurs.3.

Note that your submission may not appear immediately on our site. Ultra320 SCSI (320-MB/s bandwidth) per channel High-performance 64-bit architecture, featuring a super-scalar RISC processor New RAID XOR engine Innovative dual processor, dual XOR engine design for the SA-6404 New performance 266MHz All Rights Reserved Windows iOS Android Mac Enter to Search Popular Apps Popular Mac Apps AVG AntiVirus for Mac 5KPlayer Avast Free Mac Security VirtualDJ MacX YouTube Downloader VLC Media Player Release Notes End User License Agreements: Hewlett-Packard End User License Agreement Fixes Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis

Version:2.84 (A) (15 Jul 2008) Fixes Implemented a stripe lock algorithm to avoid potential data write errors observed during rare instances of background surface analysis initialization and I/O writes occurring on Raid Enhancements 1.

nt