Place the firmware to be updated in the directory, /compaq/swpackages on the USB key. Version:9.0.24.0 (27 Mar 2012) Enhancements Upgrade Requirement:Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to Added POST messages informing users to upgrade their HDD firmware for certain models of hard drives to the latest available firmware version on the HP web site. Fixed an issue where inquiries to the logical drive would succeed even after the drive is physically removed. check over here

Users can then configure or maintain the detected and supported devices such as HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. Provide feedback Please rate the information on this page to help us improve our content. If you are looking for an update , pickup the latest one. HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps: Place the Firmware Maintenance CD on a http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=426649

Open Windows Explorer Right-click on Computer Select "Properties" Look for the "System" heading to find the "System type" A 64-bit system may shown as: "64-bit Operating System" Subscribe to driver and Version:2.74(A) (10 Jan 2007) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. 1. Warranty status only indicates current warranty state.

Manage Split Mirror Backup This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. This option re-creates the original mirrored array with the contents of the primary array. The new arrays have the following characteristics: If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives. Enhancements Improved cache flushing and performance.

End User License Agreements: Hewlett-Packard End User License Agreement Important: The firmware update Version 2.48 contains critical bug fixes and is the minimum version required.  Please perform the update at your Type: Firmware - Storage Controller Version: 2.84 (A)(15 Jul 2008) Operating System(s): Microsoft Windows 2000 Microsoft Windows Server 2003 Microsoft Windows Server 2003 for 64-bit Extended Systems Microsoft Windows Server 2008 Added support for: HP SmartCache - accelerate data access by using SSD drives as cache Auto Replace Drive - new spare mode Full RPI - Rapid Parity Initialization Version:9.30.15.0 (26 Oct 2012) Can I transfer files from Raid 10 array with windows 7 on new computer?

Changed the SCSI ID detection algorithm for SCSI disk drive that unexpectedly changes its SCSI ID, in configurations involving duplex backplanes. The backup array always contains RAID 0 logical drives. Articles & News Forum Graphics & Displays CPU Components Motherboards Games Storage Overclocking Tutorials All categories Chart For IT Pros Get IT Center Brands Tutorials Other sites Tom's Guide Tom's IT Driver version 5.60.0.32 and newer added support for the HP Smart Array 6i controller.

Individual drivers may be available on manufacturer websites at no charge. Fixed an issue that would downshift the entire bus for a single parity error. For feedback or suggestions on ACU, please send comments to [email protected]; however, we regret that support cannot be provided through this address. Fixed an abnormal volume state issue where under certain rare conditions, a replacement drive that is in a rebuilding state in a RAID 1 or RAID 1+0 configuration may be marked

This feature is useful when you want to capture a backup before performing a risky operation. check my blog Sign-in Register Site help Skip to ContentSkip to FooterSolutionsHybrid IT with CloudMobile & IoTIT for Data & AnalyticsPublic SectorService ProvidersSmall & Midsize BusinessFinancial ServicesHealth & Life SciencesManufacturingTelecommunications All Solutions ServicesAdvisory and Heal Array Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. HP recommends for remote deployment of this package that you obtain the most recent version of the Firmware Maintenance CD and follow these steps: Place the Firmware Maintenance CD on a

Run Autorun from \_autorun\autorun_win.exe on the Firmware Maintenance CD from the USB key on a system Select the Firmware Update tab Click on the Install Firmware link to launch the HP This allows a RAID 1 volume to be split into two RAID 0 volumes and then combine the two RAID 0 volumes into a single RAID 1 volume.3. If you choose to participate, the online survey will be presented to you when you leave the Technet Web site.Would you like to participate? this content will not download on a stripped array solved Toshiba Canvio 1TB HDD will no longer open on Windows 7 after plug-in to Samsung Smart TV -HELP!

The setupact.log file did not provide any more information either. Installation: Place the Smart Component in a temporary directory.Double-click on the Smart Component.Follow the directions given by the Smart Component.Reboot your system if you would like the update to take effect Thursday, March 20, 2014 6:44 AM Reply | Quote 0 Sign in to vote Mb this helps?

From the INF you provided, it is for Windows 6.0.

Version:2.48 (A) (30 Aug 2005) Fixes Updated the battery charging firmware to reduce the frequency and duration of battery charging cycles. Added support for the 512MB Battery-Backed Write Cache (BBWC) option.6. Fixed an issue where Windows Server x64 would hang or blue screen when the Smart Array driver is installed or upgraded on a system that has greater than 7GB RAM. 2. Fixed an issue that causes the HP Insight Management Agents to display incorrect characters for the DL360 G4.3.

Very helpful Somewhat helpful Not helpful Type: Software - System Management Version: 9.40.12.0(19 Feb 2013) Operating System(s): Microsoft Windows Server 2003 Microsoft Windows XP Professional SUSE Linux Enterprise Server 9 (x86) Version:2.80(A) (25 Sep 2007) Fixes Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. Fixed Array behavior to prevent unwanted device migrations by detecting conditions, where a SCSI disk drive unexpectedly changes its SCSI ID. 3. have a peek at these guys The firmware update Version 2.48 contains critical bug fixes and is the minimum version required.  Please perform the update at your earliest convenience.

If you have previously upgraded to version 2.58 firmware another update is not needed.2. Installation:Download the offline ACU zip file and then burn/write the ISO image to the desired media (CD/DVD/USB Key/SD card) using the HP USB Key Utility for Windows   Insert the media into the Enhancements 1. Run Autorun from \_autorun\autorun_win.exe on the Firmware Maintenance CD from the USB key on a system Select the Firmware Update tab Click on the Install Firmware link to launch the HP

Make these changes: Install updated drivers for the following devices (bla bla) Storage controllers: Smart Array 6i Controller (Media Driver) I was unable to find more detailed information on why this Blog Unsubscribe About Us Overview Contact Us Take our Site Survey Testimonials Copyright © 1996 - DriverGuide is an iCentric Corporation Company. Upgrade Requirement:Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the Type: Software - System Management Version: 9.40.12.0(19 Feb 2013) Operating System(s): Microsoft Windows Server 2003 Microsoft Windows XP Professional SUSE Linux Enterprise Server 9 (x86) Microsoft Windows Server 2003 for 64-bit

For more details, refer to Customer Advisory EM041123_CW01 Version:2.34 (A) (17 Dec 2004) Fixes Fixed an issue where the battery status may be falsely reported as “failed” even though the cache module Note: In the case where the primary array is no longer available.

nt