conteHome > Hp Smart > Hp Smart Array 5i Scsi Driver

Hp Smart Array 5i Scsi Driver

It is up to you to make any changes to your grub or lilo configuration files and /etc/modules.conf (or modprobe.conf) files as needed. On-Line Spares: Up to two spare drives can be installed prior to drive failure. Showing results for  Search instead for  Did you mean:  Menu Categories Solutions IT Transformation Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Servers and Operating The ads help us provide this software and web site to you for free. weblink

The Smart Array 5i SCSI firmware is reporting version 1.92. How many drives will the Smart Array 5i support? Removed unneeded lock in sysfs code. That is, there are some kernels which have overlapping sets of controllers supported by both hpsa and cciss. Bonuses

This patch will get called only once for each controller. Click here to access the HPE Smart Array 5i Controller Server Worldwide QuickSpec in .pdf format . Note: Debian package is greatly simplified. Yes!

Q13. No, Compaq believes that data integrity is the most important feature of any of our array controller products. Does the Smart Array 5i support Single Ended SCSI devices? Just be ready to remove the driver update RPM if/when RedHat releases a kernel update with an updated cciss driver.

Please support our project by allowing our site to show ads. Upon reaching the limitation of the Smart Array 5i, any current or future Ultra2 or Ultra3 Smart Array Controller can easily replace the Smart Array 5i to increase data performance, data Cleaned up code for adding and removing logical volumes. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00329917 Please support our project by allowing our site to show ads.

End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMéxicoNederlandNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto RicoSchweizSouth The usual HP utilities, ACU, the SNMP storage agents, and cciss_vol_status should also work with hpsa. In these instances you may wish to try the source RPMs or tarballs provided here. Other than the obvious "it won't boot". 0 Kudos Reply ddmobley Occasional Visitor Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content

Recovery ROM provides a unique redundancy feature that helps ensure against controller availability. check it out Are Ultra2 and Ultra3 compatible? 5. Where does the Smart Array 5i Controller fit in the Compaq family of array controllers? A new Smart Array driver called "hpsa" has been accepted into the main line linux kernel as of Dec 18, 2009, in linux-2.6.33-rc1.

Click here to access the QuickSpec homepage, which provides access to the QuickSpecs for other regions/countries . have a peek at these guys All rights reserved. A12. Click here to check warranty status .

Yes! The system would panic when deleting many logical volumes at one time. This patch will get called only once for each controller. http://3podjobs.com/hp-smart/hp-smart-array-642-scsi-controller-driver.php Note 2: On-Line Spares can only be used with RAID level 1, 1+0, and 5.

But finding out the filename of the backup initrd will be difficult if you have already rebooted and the new initrd is not viable, so *after installation, look into /boot and How is this problem addressed with Recovery ROM? Absolutely!

Fault Recovery [ 2 ] Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure Recovery ROM: This new feature provides a unique redundancy feature that protects from a

Go to Solution. 0 Kudos Reply All forum topics Previous Topic Next Topic 5 REPLIES Matti_Kurkela Honored Contributor Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to HP does supply binary RPMs and driver diskettes (for loading drivers during OS installation) for supported Linux distributions on hp.com. Write-back cache is vulnerable to power drops. All other Smart Array controllers are connected through a PCI slot.

Fixed wrong usage of a pointer for sysfs symlink. A17. Why do i see many drivers ? this content Here's a sample report from arrayprobe 2.0.

The new initrd will take effect on next boot.If the new module turns out to have fatal errors (which is very unlikely), you could revert to using the old version simply No longer spins up idle spare drives. Note 5: Future support planned for ProLiant ML370 G2 servers. Below is a list of drivers that may be suitable for your device.

If you've been using cciss already on these controllers, it is not recommended that you attempt to upgrade your running system to switch from cciss to hpsa unless you have a The current list of supported controllers for hpsa: Gen6/7 Controllers Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m Are Ultra2 and Ultra3 compatible? Initially, there was some overlap in the boards which these two drivers support.

OS distros with warnings. Changes since 1.10: Support for new Smart Array controllers was added and added the ability to report status of non-volatile cache.

nt